ICT / ITE / Medical Power Supply/Class 2/Household Power Supply

GTM96180-18VV H/M Image
Model Image4th Edition of Medical IEC60601, IEC 62368, IEC 60335, LPS,  DOE EPS 2.0 Level VI Compliant Power Supply / Charger / AC Adapter, 18W with 4-48VDC output options 4th Edition of Medical IEC60601, IEC 62368, IEC 60335, LPS,  DOE EPS 2.0 Level VI Compliant Power Supply / Charger / AC Adapter, 18W with 4-48VDC output options
Information
Model NumberGTM96180-18VV H/M
Description4th Edition of Medical IEC60601, IEC 62368, IEC 60335, LPS, DOE EPS 2.0 Level VI Compliant Power Supply / Charger / AC Adapter, 18W with 4-48VDC output options 4th Edition of Medical IEC60601, IEC 62368, IEC 60335, LPS, DOE EPS 2.0 Level VI Compliant Power Supply / Charger / AC Adapter, 18W with 4-48VDC output options
Agency Documentshttp://www.globtek.info/certs/GTM96180/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjRI5EAN
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjRI5EAN
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MjRI5EAN
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjRI5EAN
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjRI5EAN
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MjRI5EAN
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MjRI5EAN
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MjRI5EAN
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in / Collegamento a presa elettrica
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / Alimentatore AC-DC di tipo switching
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A
Max Output Power Rating (W)18
Output Voltage Range (V)4-48
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP42 (Optional IP54-IP55)
Size (mm)74*43.5*36.8
Enclosure

User-added image
LED INDICATORGreen Power ON indicator LED standard. May be ordered without LED as an option.
 
3D File Downloadhttps://www.globtek.com/dl/GTM96180-WALL-PLUG%20(5).igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM96180-1207-2.0-CF*52.512.5
GTM96180-1507-2.0*5315
GTM96180-1207-2.0*52.412
GTM96180-1607-2.0*53.216
GTM96180-1807-1.05*5.953.02518
GTM96180-1811-2.0*9218
GTM96180-1511-2.0-CF*91.6614.94
GTM96180-1511-1.0-CF*101.515
GTM96180-1817.9-7.9*101.818
GTM96180-1517.9-5.9-CF*121.2515
GTM96180-1817.9-5.9*121.518
GTM96180-1817.9-4.4*13.51.3317.96
GTM96180-1817.9-3.9*14.01.28517.99
GTM96180-1817.9-2.9*151.218
GTM96180-1517.9-2.9-CF*15115
GTM96180-1817.9-1.9*16.01.1217.92
GTM96180-1817.9-0.9*17.01.0517.85
GTM96180-1830-12.0*18118
GTM96180-1530-12.0-CF*180.8314.94
GTM96180-1830-11.0*190.9417.86
GTM96180-1830-10.0*200.918
GTM96180-1830-8.0*220.8117.82
GTM96180-1530-6.0-CF*240.62515
GTM96180-1130-6.0*240.4510.8
GTM96180-1830-6.0*240.7518
GTM96180-1830*300.618
GTM96180-1848-12.0*360.518
GTM96180-1848 (6w)*480.1256
GTM96180-1548-CF*480.3114.88
GTM96180-1848*480.37518
GTM96180-18VV H/M-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant)
Inrush Current:30A/60A maximum, cold start @ 115VAC/230VAC input, respectively
Efficiency:DoE Level VI compliant, EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ nominal line and full load
Output Regulation± 5% max. (measured at the output connector)
Line Regulation:± 0.5% typ. (measured at the output connector, full load)
Ripple:1% or 100mV, whichever is greater (measured using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation (with 40-70% load step), 1ms typ. recovery time 
Hold-up Time:8ms typ. @ nominal line and full load
Power On Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Voltage Protection:110-130% of nominal output voltage
Short-Circuit Protection:Auto-restart
Over-Current Protection:110-160% of rated output current (Current limit range is determined by normal output power rating, not derated power level)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
See derating table for output power capability at other temperatures.
Extended low temperature range available as a custom option.
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Ingress protection:IP42 standard, IP52 available as a special option
Cooling:Convection
RoHS:Complies with EU 2011/65/EU amended by EU 2015/863 and China SJ/T 11363-2006

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models)
Touch Current:Class I models: < 20uA
Class II models: <75uA
Earth Leakage Current:Class I models: <300uA
Class II models: N/A
Isolation Options:Floating output or Class I earthed output (desktop models)
Earth Continuity Test:< 0.1 ohm between AC inlet earth pin and PCB termination point
Means of Protection:2 x MOPP
Compliant Standards:See listing at the end of this document.

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 8KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Wall plug-in, changeable blades (Class II only)
Desktop housing, extended housing: C6, C8, C14, or C18 IEC inlet (Class I or Class II)
Markings:Label or laser printed
 

Special Options

  1. Removal of LED (optional)
  2. Custom cord-sets (custom cord and/or connector types). Note: 5VDC USB power supplies with Micro-B or Type-C connectors have a voltage regulation specification of ±8% (4.6V to 5.4V).
  3. Custom markings
  4. Short term output surge capability
  5. Reduced leakage current versions (10uA max) for Type-CF medical applications and/or for AC noise sensitive equipment. (15W or less, 5 to 24V output voltage range.)
  6. Tightened output voltage tolerance
  7. Reduced output voltage ripple
  8. Improved reliability PCB laminate with plated-through-holes for IPC610 Class 2 compliance
  9. Custom housing colors
  10. Quasi constant-current output for SLA (lead-acid) battery charging applications
Derating CurveUser-added image
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Colorwhite
Master Carton Size (mm)480 x 450 x 205
Gross Weight (kg)15.2
Label Width (mm)29.8
Label Height (mm)20.8
Input Configuration
DescriptionBlade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php
Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf
Video: Q-Blade Style Instruction Video


User-added image
 

INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified

01. United States / Canada / Japan  NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R)
02. Australian AS 3112 configuration: SAA 2 blade/ IEC TYPE I, Class II; AU P/N: Q-SAA(R)
03. UK BS 1363 configuration: UK 3 blade with dummy Ground/ IEC TYPE G, Class II; GB P/N: Q-UK(R)
04. European CEE 7/16 configuration: Europlug 2 pins/ IEC TYPE C [WORKS IN TYPE E&F], Class II; EU P/N: Q-EU(R)
05. Korean KS C8305 configuration: 2 pins/SIMILAR TO IEC TYPE C, Class II; KR P/N: Q-KR(R)
06. Argentina IRAM 2073 configuration: 2 blades/SIMILAR TO IEC TYPE I; AR P/N: Class II Q-AR(R)
07. China GB 2099 configuration: 2 blades/SIMILAR TO TYPE A, Class II; CN P/N:Q-CN(R)
08. India IS 1293 6A/BS546 configuration: 5A, 3 pins with Dummy Ground, Class II/IEC TYPE D; IN P/N: Q-IN(R)
09. IEC60320/C18 Inlet, Class II; P/N: Q-C18(R)
10. Brazilian NBR6147 configuration: 2 pins, Class II;SIMILAR TO IEC TYPE C BR P/N: Q-BR(R)
11. South Africa SABS164-1 and India
 IS 1293, IS694, 16A type plug, 3 round prongs, Class II + dummy ground, IEC TYPE M P/N: Q-SANS164-1-16A(R)
12. South Africa SABS164-4, 3 round prongs with a notched prong @ 0º, Class II + dummy ground, IEC TYPE M Red, P/N:
Q-SANS164-4L-16A(R)
13. South Africa SABS164-4, 3 round prongs with a notched prong @ -
53º, Class II + dummy ground, Blue, IEC TYPE M, P/N:
Q-SANS164-4C-16A(R)
14. South Africa SABS164-4, 3 round prongs with a notched prong @ +53º, Class II + dummy ground, Black,IEC TYPE M P/N:
Q-SANS164-4R-16A(R)

Kits

01. Q-KIT: 1,2,3,4 above
02. Q-KIT-INTL: 2,3,4 above
03. Q-KIT-6: 1,2,3,4,5,6 above
04. Q-KIT-7: 1,2,3,4,5,6,7 above
05. Q-KIT-8: 1,2,3,4,5,6,7,8 above

Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageBook 60335 up to 36 Volts

No Logo Applicable

IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) for GTM96180 only

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)

No Logo Applicable

CB report to IEC 61558-2-16_2009 + A1_2013 IEC 61558-1_2005 2nd Edition + A1_2009 EN 61558-1-16_2009 EN 61558-1_2005 + A1_2009.pdf
 User-added imageCCC to GB4943. 1-2011; GB9254-2008; GB17625. 1-2012 with Tropical and Altitude up to 5000 m approval.

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27, Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued: 2007/03/27 Ed: 2 (R2012) Amd.
User-added image
Class 2 Power Unit
 
cETLus-Cert 4007497 UL1310 Recognized Component up to 36 volts
User-added image
 
AAMI ES60601-1 Issued: 2012/08/20 Med Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, 3rd Edition Issued: 2014/03/01 - Med Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: GTM96180 only
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1 for GTM96180 family only
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
No LogoGreenhouse and Energy Minimum Standards (GEMS) for model GTM96180-1817.9-5.9
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageFuse 60335 T1.6A 250VAC Up to 36 volts
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added imageBureau Of Indian Standards for GTM96180 5v, 5.95v, 7.5v, 9v, 12v, 15v, 19v, 20v, 24v, 48v
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561.pdf, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V?30V]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561, to J62368-1(H30) , J55032(H29), J3000(H25) ,[30V?60V]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V or less]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageKorea HU10499-19038A (for GTM96180-1830-6.0) 19V-30V
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageNOM MEXICO -ANCE FOR GTM96180 12V only (pending)
User-added image
 
Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added imageSemko S-Mark-Cert-EN60950-1 and (EN60601-1 for GTM96180 family only).
User-added imageSingapore 181312-12 GTM96180-1817.9-5.9
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample RequestDistributor Stock (Click to order)
2940695.03.0USB Type-C Connector
3590555.03.6T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
2332055.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
8332045.03.0Female Barrel Right Angle, 5.5*2.1*11mm with internal Spring Clip and Locking Notch or Equal
WR9QA3600CCPNAIMR6B5.03.6Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal30
4903595.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
WR9QA3000LCP-IMR6B5.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal134
3590535.03.6Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
2450065.953.025Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
WR9QB3000T00NAIMR6B5.953.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)38
WR9QC2400T00NAIMR6B7.52.4T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)55
WR9QD2000LCPCIMR6B9.02.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal180
WR9QD2000T00NAIMR6B9.02.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)60
5757469.02.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
3766029.02.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
35905712.01.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
22339712.01.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
61013312.01.5Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
WR9QE1500T00NAIMR6B12.01.5T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)7
47895115.01.2Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
WR9QG1200T00NAIMR6B15.01.2T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)31
35619818.01.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
WR9QH1000T00NAIMR6B18.01.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)142
35906124.00.75Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
35906024.00.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
25272324.00.75T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
29286324.00.8Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
WR9QX375T00NAIMR6B48.00.375T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)60
WR9QX375PPOENR6B48.00.375Power & Data ( 2 Jacks), RJ45 jacks mounted in 94V-O polycarbonate non-vented enclosure. Black color with White sillkscreen located on top of enclosure. Dimensions 50 X 45 X 28 mm.58

Cos’è un alimentatore per applicazioni medicali conforme IEC 60601-1?

 

Si tratta di un convertitore che permette di alimentare, tipicamente in DC, un sistema o un componente in ambito elettromedicale, prelevando tensione AC dalla rete. Tipicamente, il case è in materiale plastico e la spina può essere a 2 o 3 poli. Esistono anche versioni open frame da alloggiare all’interno di apparecchiature medicali. La progettazione è eseguita secondo gli standard internazionali e alcuni requisiti sono specifici e particolari in confronto alle più comuni applicazioni per informatica e telecomunicazioni. Che differenze ci sono per quanto attiene la certificazione allo standard IEC 60601-1 Quarta Edizione rispetto alla vecchia IEC 60601-1 Terza Edizione?

Di fatto, le certificazioni in materia di sicurezza fissate dalla Terza Edizione continuano a valere mentre per quanto attiene gli aspetti EMI/EMC si fa riferimento alla Quarta.

Qual è la differenza fra un alimentatore per usi medicali certificato IEC 60950-1 rispetto ad uno certificato IEC 60601-1 ?

 

Sia la IEC 60950-1 che la IEC 60601-1-2 si riferiscono ad alimentatori AC/DC per uso interno o esterno ma con diversi requisiti relativi alle specifiche del sistema da alimentare. Le funzionalità di base sono ovviamente le stesse, ci si riferisce per esempio a tensione di uscita e caratteristiche meccaniche ma, per il resto, ci sono diverse differenze. I dispositivi IEC 60601, in confronto all’altra tipologia, devono essere in grado di sopportare tensioni elevate e avere basse correnti di dispersione. Inoltre, con riferimento al carico, occorre distinguere fra sistemi MOOP e MOPP. Le apparecchiature medicali devono includere uno o più sistemi di protezione ovvero Means of Protection (MOPs) per isolare i pazienti e gli operatori dal rischio di elettrocuzione. Si tratta di isolamento di sicurezza, terra di protezione, distanze di isolamento in aria o altri sistemi contro il contatto diretto. Tutti questi sistemi sono spesso utilizzati in combinazione fra loro. La norma IEC 60601-1 Terza Edizione fissa delle differenze relativamente ai rischi per i pazienti e per gli operatori. Pertanto, un sistema MOP può quindi essere classificato come MOPP (Means of Patient Protection) oppure come MOOP (Means of Operator Protection). La principale differenza sta nelle distanze limite di isolamento. Per esempio, per ottenere la rispondenza ai requisiti 2 x MOPP il livello di isolamento da garantire durante i test che prevedono l’applicazione di 4000 Vac con una distanza di di 8 mm è il doppio rispetto al caso MOPP.

Cos’è un alimentatore per usi medicali IEC 60601-1-2 e qual è la differenza fra la tipologia BF e CF?

Tali sigle si riferiscono alle tipologie B ovvero “body”, BF ovvero “body floating type” e CF ovvero “cardiac floating type. Ci si riferisce in pratica alle modalità di applicazione del dispositivo medicale al corpo del paziente con requisiti tecnici che riguardano tensione di isolamento, correnti disperse, ecc. La parola floating si riferisce all’assenza di collegamento di terra. Si tratta in questo caso di dispositivi in Classe II con isolamento doppio o rinforzato. La tipologia B si riferisce a dispositivi che operano nelle vicinanze del paziente così come definito dalla norma IEC 60601-1 ovvero senza contatto elettrico diretto e con collegamento a terra. Si tratta, per esempio, di sistemi di illuminazione, sistemi di automazione per letti, distributori automatici di medicine, macchinari a raggi x, ecc. Nel caso dei sistemi BF, invece, vi è una stretta prossimità fra paziente e apparecchiatura, si tratta per esempio di endoscopi, sistemi di monitoraggio dei parametri vitali, ecc. Nel caso CF, il collegamento è invece diretto come avviene per defibrillatori, pacemaker, elettrodi ECG intracardiaci, ecc. Per ovvie ragioni, in questo ultimo caso, è richiesto un elevatissimo livello di protezione contro l’elettrocuzione.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è il livello VI di efficienza?

L’ordinamento numerico da I a VI si riferisce alla marcatura internazionale di prodotti in relazione al livello di efficienza di un certo prodotto. I requisiti previsti per la classificazione si basano sulla misura dell’efficienza durante il funzionamento e sulla valutazione del consumo a vuoto e a diversi livelli di carico. Il consumo a vuoto viene registrato in assenza di carico o con carico disconnesso. Il livello di efficienza VI è ormai obbligatorio in diverse nazioni per specifici prodotti o per specifiche applicazioni. La Direttiva Europea Eco-design 2009/125/EC ha di fatto inserito, per i Paesi Europei, i requisiti del livello di efficienza VI nell’ambito delle normative che regolano la vendita e l’importazione di alimentatori per uso esterno.

In cosa consiste la normativa europea CoC Tier 2?

Si tratta di una serie di norme che stabiliscono degli obiettivi di efficienza energetica per gli alimentatori e adattatori AC-DC. Sono pubblicate dalla Renewable Energy Unit del centro JRC (Joint Research Centre) della Commissione Europea. I requisiti fissati da tale norma non fissano degli obblighi di legge ma possono essere applicati su base volontaria.

Cos’è un alimentatore AC-DC di tipo plug-in ?

Anche noti come adattatori AC o convertitori AC-DC, si tratta di una tipologia di alimentatori per uso da esterno. Alcune apparecchiature elettriche necessitano di alimentazione di potenza ma non dispongono di una circuiteria interna per poter gestire un collegamento diretto alla rete. In casi del genere, un alimentatore AC viene utilizzato per convertire la tensione AC di rete in tensione DC adatta per l’alimentazione dell’apparecchiatura in questione.

Come funziona un adattatore AC-DC?

L’adattatore AC-DC è un convertitore da esterno integrato all’interno di un piccolo case costruito attorno ad una spina AC per collegamento alla rete, da cui derivano anche i vari termini plug, wall plug in, plug-in o plugtop. Una volta collegato alla rete elettrica AC, la tensione viene convertita in DC per l’alimentazione del carico attraverso il cavo di uscita.

Richiesta informazioni

Model

Call
Email
💬
Text
💁
Chat
?
Richiedi un preventivo
Ti possiamo aiutare?
Ti possiamo aiutare?