ICT / ITE / Medical Power Supply

GTM43007-BWWVV-F Image
Model ImageGTM43007-BWWVV-F, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030  3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: CB 62368; ETL 62368; UKCA; LPS 60950; Conforms to 62368-1; CCC; Book 60601; CB 60601-1 2MOPP; CE; China RoHS; Class I; GOST-R; RoHS; Ukraine; WEEE; CE; FCC; Fuse 60335; WDaE; CB 60950; CB EN/IEC 60335-1; cETLus ES60601; cETLus; cETLus 60601-1 3rd; Level V; S-Mark IEC/EN 60601-1 60950; Fuse 60335; GTM43007-BWWVV-F, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030  3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: CB 62368; ETL 62368; UKCA; LPS 60950; Conforms to 62368-1; CCC; Book 60601; CB 60601-1 2MOPP; CE; China RoHS; Class I; GOST-R; RoHS; Ukraine; WEEE; CE; FCC; Fuse 60335; WDaE; CB 60950; CB EN/IEC 60335-1; cETLus ES60601; cETLus; cETLus 60601-1 3rd; Level V; S-Mark IEC/EN 60601-1 60950; Fuse 60335;
Information
Model NumberGTM43007-BWWVV-F
DescriptionGTM43007-BWWVV-F, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: CB 62368; ETL 62368; UKCA; LPS 60950; Conforms to 62368-1; CCC; Book 60601; CB 60601-1 2MOPP; CE; China RoHS; Class I; GOST-R; RoHS; Ukraine; WEEE; CE; FCC; Fuse 60335; WDaE; CB 60950; CB EN/IEC 60335-1; cETLus ES60601; cETLus; cETLus 60601-1 3rd; Level V; S-Mark IEC/EN 60601-1 60950; Fuse 60335; GTM43007-BWWVV-F, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: CB 62368; ETL 62368; UKCA; LPS 60950; Conforms to 62368-1; CCC; Book 60601; CB 60601-1 2MOPP; CE; China RoHS; Class I; GOST-R; RoHS; Ukraine; WEEE; CE; FCC; Fuse 60335; WDaE; CB 60950; CB EN/IEC 60335-1; cETLus ES60601; cETLus; cETLus 60601-1 3rd; Level V; S-Mark IEC/EN 60601-1 60950; Fuse 60335;
Agency Documentshttp://www.globtek.info/certs/GTM43007/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000Mgc6sEAB
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000Mgc6sEAB
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000Mgc6sEAB
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000Mgc6sEAB
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000Mgc6sEAB
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000Mgc6sEAB
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal / Per installazione interna, versione 'Open Frame'
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / Alimentatore AC-DC di tipo switching
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)60
Output Voltage Range (V)5-48
EfficiencyN/A
Ingress ProtectionN/A
Size (mm)101.6x50.8x23.6 for 5V-14V models, 101.6x50.8x22.5 for 15V-48V models
Enclosure
Drawing for the Low Voltage (Range 5-14V):

User-added image





Drawing for the Hihg Voltage (Range 15-48V):

User-added image





















 
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM43007-B3005-F*5630
GTM43007-B3007-1.0-F*6530
GTM43007-B3007-F*74.2829.96
GTM43007-B3809-1.5-F*7.5537.5
GTM43007-B4509-F*9545
GTM43007-B4512-2.0-F*104.545
GTM43007-B4512-F*123.7545
GTM43007-B6012-F*12560
GTM43007-B6015-F*15460
GTM43007-B6018-F*183.3359.94
GTM43007-B6024-5.0-F*193.1559.85
GTM43007-B6024-4.0-F*20360
GTM43007-B6024-F*242.560
GTM43007-B6036-8.0-F*282.1459.92
GTM43007-B6036-6.0-F*30260
GTM43007-B6036-F*361.6659.76
GTM43007-B6048-F-8.0*401.560
GTM43007-B6048-F*481.2560
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 3% measured at the output connector
04. Line Voltage Regulation: +/- 0.5% maximum measured at full load
05. Output Ripple (Vp-p): 1% or 150 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected 3” from the output connector .
06. Turn-ON/OFF: 5% maximum,1 mS typical recovery time for 25% step load
07. Turn-ON Delay: 3 Sec max
08. Hold-Up Time:8 mS typical @ nominal input voltage and full load
09. Inrush Current: 30A maximum  @ 115 Vac input, 60A maximum  @ 230 Vac input
10. Switching Frequency: 65 KHz typical
11. Efficiency: 87% @115Vac, 89% @ 230Vac typical at full load
12. No Load Power: < 300mW @ 230Vac

B) PROTECTION
01. Overvoltage Protection: 110% to 130% of nominal output voltage, and less than 60Vdc
02. Short Circuit/Over-load: momentary short circuit protected, output will auto recover upon removal of short
03. Input Protection: Input line fusing and 300Vac MOV

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac / 5656Vdc from primary to secondary
02.  Output Isolation Options:  Class I or Class II
03. Earth Leakage Current: Does not exceed 300uA in NORMAL CONDITION and 1000uA in SINGLE FAULT CONDITION
04. Output Leakage Current: Does not exceed 75uA NC(Normal condition) 300uA SFC(single fault condition)
05. Means of Protection: 2 x MOPP
06. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4, CISPR11 and CISPR22
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A
Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 20kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER
01. MTBF: 1,000,000 Hours @ 45°C ambient temperature, Full Load
02. Operating Temperature: -10°C to 45°C ambient temperature
03. Humidity: 0% to 95% relative humidity
04. Storage Temperature: -30°C to 80°C
05. Cooling: Convection
06: Elevation: 5000M
07. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006


F) MECHANICAL  FORMAT
01. Type: Open Frame
02. Size: A suffix version, (2”x3”), 76.2 x 50.8 x 30.5 mm
03. Size: B suffix version, (2”x4”), 101.6 x 50.8 x 30.5 mm
04. Size: C suffix version, (3”x5”), 127.0 x 76.2 x 30.5 mm


G) SPECIAL OPTIONS
01. Custom Label Markings
02. Short term Output Surge Capability
03. Reduced Leakage Current versions
04. Tightened output voltage tolerance
05. Reduced output ripple level
06. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
07. Low Temperature operation, down to -40°C
08. Quasi Constant Current Output, for Lead-Acid Battery Charger Applications
09. Special Input or Output Connectors
10. Over-Temperature Protection, Latched Shut-Down
 
Derating CurveUser-added image
 
Qty (ea.)/Carton90
Individual Box/Gift Box Size (mm)110*60*40
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)380 x 380 x 250
Gross Weight (kg)15.2
Label Width (mm)
Label Height (mm)
Input Configuration
DescriptionMolex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral
User-added image     
                                                     User-added image
    
Optional Input Wiring Kits are available:
PN/Ordering No   Length  End A   End B
XHP410070M7MLX3(R)70JST XHP-4  Molex 09-93-0300
C810070M6MLX3(R)60IEC60320 C8  Molex 09-93-0300
C1410070M6MLX3(R)60IEC60320 C14  Molex 09-93-0300
 Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC60601-1 2005 A1+C1+C2 2016-2-4 and or EN 60601-1:2006 3.1rd Edition 2xMOPP
No Logo CB Report EN60950-1

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008 for GT*43007
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN 60601-1-2:2015 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
Conforms to ANSI/AAMI ES 60601-1:2005
Cert.to CAN/CSA Std. C22.2
 
cETLus ANSI_AAMI ES60601-1_2005
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005/A1:2012 Issued: 2012/08/20 Medical electrical equipment ? Part 1: Amendment 1; CAN/CSAC22.2 No. 60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
FCC PART 15 CLASS B
User-added imageFuse 60335 T2.0A 250VAC Up to 36 volts
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageSemko S-Mark-Cert-EN60601-1 and EN60950-1
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
WDaEAppliances can be used in warm damp equable climates
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
27069718.03.3Molex 2.54mm Pitch 4-Pin Header PN: 22-11-2042 MATES W/ PN: 22-01-2047 or Equivalent

Cos’è un alimentatore per applicazioni medicali conforme IEC 60601-1?

 

Si tratta di un convertitore che permette di alimentare, tipicamente in DC, un sistema o un componente in ambito elettromedicale, prelevando tensione AC dalla rete. Tipicamente, il case è in materiale plastico e la spina può essere a 2 o 3 poli. Esistono anche versioni open frame da alloggiare all’interno di apparecchiature medicali. La progettazione è eseguita secondo gli standard internazionali e alcuni requisiti sono specifici e particolari in confronto alle più comuni applicazioni per informatica e telecomunicazioni. Che differenze ci sono per quanto attiene la certificazione allo standard IEC 60601-1 Quarta Edizione rispetto alla vecchia IEC 60601-1 Terza Edizione?

Di fatto, le certificazioni in materia di sicurezza fissate dalla Terza Edizione continuano a valere mentre per quanto attiene gli aspetti EMI/EMC si fa riferimento alla Quarta.

Qual è la differenza fra un alimentatore per usi medicali certificato IEC 60950-1 rispetto ad uno certificato IEC 60601-1 ?

 

Sia la IEC 60950-1 che la IEC 60601-1-2 si riferiscono ad alimentatori AC/DC per uso interno o esterno ma con diversi requisiti relativi alle specifiche del sistema da alimentare. Le funzionalità di base sono ovviamente le stesse, ci si riferisce per esempio a tensione di uscita e caratteristiche meccaniche ma, per il resto, ci sono diverse differenze. I dispositivi IEC 60601, in confronto all’altra tipologia, devono essere in grado di sopportare tensioni elevate e avere basse correnti di dispersione. Inoltre, con riferimento al carico, occorre distinguere fra sistemi MOOP e MOPP. Le apparecchiature medicali devono includere uno o più sistemi di protezione ovvero Means of Protection (MOPs) per isolare i pazienti e gli operatori dal rischio di elettrocuzione. Si tratta di isolamento di sicurezza, terra di protezione, distanze di isolamento in aria o altri sistemi contro il contatto diretto. Tutti questi sistemi sono spesso utilizzati in combinazione fra loro. La norma IEC 60601-1 Terza Edizione fissa delle differenze relativamente ai rischi per i pazienti e per gli operatori. Pertanto, un sistema MOP può quindi essere classificato come MOPP (Means of Patient Protection) oppure come MOOP (Means of Operator Protection). La principale differenza sta nelle distanze limite di isolamento. Per esempio, per ottenere la rispondenza ai requisiti 2 x MOPP il livello di isolamento da garantire durante i test che prevedono l’applicazione di 4000 Vac con una distanza di di 8 mm è il doppio rispetto al caso MOPP.

Cos’è un alimentatore per usi medicali IEC 60601-1-2 e qual è la differenza fra la tipologia BF e CF?

Tali sigle si riferiscono alle tipologie B ovvero “body”, BF ovvero “body floating type” e CF ovvero “cardiac floating type. Ci si riferisce in pratica alle modalità di applicazione del dispositivo medicale al corpo del paziente con requisiti tecnici che riguardano tensione di isolamento, correnti disperse, ecc. La parola floating si riferisce all’assenza di collegamento di terra. Si tratta in questo caso di dispositivi in Classe II con isolamento doppio o rinforzato. La tipologia B si riferisce a dispositivi che operano nelle vicinanze del paziente così come definito dalla norma IEC 60601-1 ovvero senza contatto elettrico diretto e con collegamento a terra. Si tratta, per esempio, di sistemi di illuminazione, sistemi di automazione per letti, distributori automatici di medicine, macchinari a raggi x, ecc. Nel caso dei sistemi BF, invece, vi è una stretta prossimità fra paziente e apparecchiatura, si tratta per esempio di endoscopi, sistemi di monitoraggio dei parametri vitali, ecc. Nel caso CF, il collegamento è invece diretto come avviene per defibrillatori, pacemaker, elettrodi ECG intracardiaci, ecc. Per ovvie ragioni, in questo ultimo caso, è richiesto un elevatissimo livello di protezione contro l’elettrocuzione.

Cos’è un alimentatore AC-DC di tipo open frame ?

Anche noti come convertitori AC-DC, si tratta di una tipologia di alimentatori per uso da interno. Gli alimentatori AC-DC open frame sono spesso integrati in altri sistemi o alloggiati in particolari case metallici ed utilizzati per convertire la tensione da AC a DC.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Come funziona un adattatore AC-DC?

L’adattatore AC-DC è un convertitore da esterno integrato all’interno di un piccolo case costruito attorno ad una spina AC per collegamento alla rete, da cui derivano anche i vari termini plug, wall plug in, plug-in o plugtop. Una volta collegato alla rete elettrica AC, la tensione viene convertita in DC per l’alimentazione del carico attraverso il cavo di uscita.

Richiesta informazioni
Call
Email
💬
Text
💁
Chat
?
Richiedi un preventivo
Ti possiamo aiutare?
Ti possiamo aiutare?