ICT / ITE / Medical Power Supply

GTM962251PWWWVVX-XF Image
Model ImageGTM962251PWWWVVX-XF, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; UKCA; CB 60601-1; Conforms to 62368-1; CB 60950; cETLus 60950-1; CB 62368; Morocco; ETL 62368; ETL; CE; CCC (pending); GTM962251PWWWVVX-XF, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; UKCA; CB 60601-1; Conforms to 62368-1; CB 60950; cETLus 60950-1; CB 62368; Morocco; ETL 62368; ETL; CE; CCC (pending);
Information
Model NumberGTM962251PWWWVVX-XF
DescriptionGTM962251PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; UKCA; CB 60601-1; Conforms to 62368-1; CB 60950; cETLus 60950-1; CB 62368; Morocco; ETL 62368; ETL; CE; CCC (pending); GTM962251PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; UKCA; CB 60601-1; Conforms to 62368-1; CB 60950; cETLus 60950-1; CB 62368; Morocco; ETL 62368; ETL; CE; CCC (pending);
Agency Documentshttp://www.globtek.info/certs/GTM96225xP%20/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000Ph0MxEAJ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000Ph0MxEAJ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000Ph0MxEAJ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000Ph0MxEAJ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000Ph0MxEAJ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000Ph0MxEAJ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal / Per installazione interna, versione 'Open Frame'
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / Alimentatore AC-DC di tipo switching
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)3A
Max Output Power Rating (W)225
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress Protectionna
Size (mm)103.5 (L) x 62.3 (W) x 40.0 (H)
EnclosureUser-added image
User-added image

Customer may need to provide EMI shielding if not in metal chassis


 
3D File Downloadhttps://www.globtek.com/dl/GTM962251PWWWVVX-XF.igs
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM962251P22512A-F*1218.75225
GTM962251P22515A-F*1515225
GTM962251P22516-F*1614.06224.96
GTM962251P22516A-F*1614.06224.96
GTM962251P22518A-F*1812.5225
GTM962251P22518-F*1812.5225
GTM962251P22519A-F*1911.84224.96
GTM962251P22524A-F*249.37224.88
GTM962251P22530A-F*307.5225
GTM962251P22536-F*366.25225
GTM962251P22536A-F*366.25225
GTM962251P22538A-F*385.92224.96
GTM962251P22548A-F*484.69225.12
GTM962251P22554A-F*544.17225.18
* (Final ordering #/Part No to be defined)
Specifications

Features

  • High power density 2" x 4" format (3" x 5" and 4.22" x 7" formats also available)
  • 2" x 4" version available in L-frame and cage configurations
  • Low conducted & radiated EMI: Class B without external filters, ferrites, or metal planes (all input configurations, into resistive load)
  • Class I, Class II, or Class II with Functional Earth input configurations
  • ITE/ICT and medical (2 x MOPP) certified
  • Auxiliary +12V output

Input

Input Voltage:Specified: 85-264VAC, Nameplate: 100-240VAC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Input Current:2.75A typ. @ 85VAC, 1.0A typ. @ 230VAC (full load)
No Load Input Power:<150mW
Inrush Current:<75A @ 230VAC (cold start @ 25°C)
Efficiency:90 - 95% typ. (full load)
Power Factor:>0.95 @ 115VAC, >0.90 @ 230VAC, 225W output
>0.90 @ 115VAC, >0.85 @ 230VAC, 100W output

Output

Output Power:225W (10CFM forced air)
140W (natural convection)
Ratings are inclusive of aux output power
Turn-on Delay:< 1 second @ 85VAC
Output Voltage Tolerance:± 2.0% (worst case, set point + load/line regulation)
Load Regulation:± 0.5% (measured at connector)
Line Regulation:± 0.2% (measured at connector)
Ripple:1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Transient Response:<5% deviation (with 25% load step), recovery to within 1% in 1ms
Startup Overshoot:<5% (full load)
Hold-up Time:10ms min. (full load)
Aux Output Voltage Regulation:12V ± 2V (10V min. / 14V max.), for 0A ≤ IAux 1.2A

Aux regulation guaranteed when main output power ≥ 15% of 225W rating (~34W).

For main output power < 15%, aux output voltage may drop to < 50% of nominal rating, depending on aux output load. Please check with your system.
For main output = 12V, aux output voltage is same as main output.
Aux Output Current:1.2A (10CFM forced air)
0.8A (natural convection)
Output Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, dual fuses (line + neutral)
Over-Voltage Protection:110-130%. Latched-off, cycle AC to reset
Over-Current Protection:130% typical, auto-recovery
Short Circuit Protection:Non-latched with auto-recovery
Over-Temperature Protection:NTC temperature sensor embedded in transformer, trip between 115 - 120°, latched-off, cycle AC to reset (auto-recovery available as special option)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 50°C (full output power), -25°C to 80°C (derated)
Storage Temperature:-30°C to 85°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m max.
Vibration:Conforms to EN60068-2-6, ISO80601-2, EN1789

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth
Touch Current:3-conductor input - NC: <25µA, SFC: <200µA
2-conductor input - NC: <65µA, SFC: <140µA
Earth Leakage Current3-conductor input: <200µA
2-conductor input: N/A
Means of Protection:2 x MOPP
Primary-Secondary Bridging Capacitance:Two IEC60384-14 certified Y1 capacitors in series

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11/CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals)
Radiated RF Immunity:EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 30A/m
Voltage Dip Immunity:EN61000-4-11

Mechanical Formats

GTM962250P:Open-frame
No suffix: 2" x 4" style, 101.6*50.8*30.0mm, 170g
-C suffix: 3" x 5" style, 127.0*64.8*30.0mm, 180g
-D suffix: 4.22" x 7" style, 177.8*107.2*30.0mm, 190g
GTM962251P:L-frame: 103.5*62.3*40.0mm, 230g
GTM962252P:Cage: 103.5*62.3*40.0mm, 250g
Note 1:The open-frame format meets the above EMC specifications as a standalone unit. However, an L-frame or cage version may help to further improve EMI performance, or to help address other system level electrical/mechanical requirements.

Input/Output Connectors

Earth Terminal (J0):Connector on PCB: Kang Yang PCH250 (0.250" x 0.031" Faston)
Recommended mate: TE Connectivity/AMP 2-520184-2
Note: Leave earth terminal disconnected for Class II input
Input Connector (J1):Connector on PCB: JST B2P3-VH
Pin 1: Line, Pin 2: Not used, Pin 3: Neutral
Recommended mate: JST VAR-2 (housing), JST SVA-41T-P1.1 (terminals)
Main Output Connector (J2):Connector on PCB: JST B6P-VH
Pin 1: COM, Pin 2: COM, Pin 3: COM , Pin 4: +VOUT, Pin 5: +VOUT, Pin 6: +VOUT
Recommended mate: JST VHR-6N (housing), JST SVH-21T-P1.1 (terminals)
Aux Output Connector (J3):Connector on PCB: Molex 22-04-1021
Pin 1: COM, Pin 2: +FAN
Recommended mate: Molex 22-01-1022 (housing), Molex 2759 (terminals)

Special Options

  • Custom labels/markings
  • Short term output surge capability
  • Reduced touch current
  • Reduced output ripple
  • Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  • IEC61000-3-2 Class-C line harmonics for LED lighting applications
  • Non-latching (auto-recover) over-temperature protection
  • Potentiometer to adjust/trim output voltage
  • Custom aux output voltages (5V to 12V), available for main output voltages from 12-24V

Fan Airflow

  • For full 225W output power, the fan should provide at least 10CFM in the direction noted below.

User-added image

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cellular Packag
Individual Box/Gift Box Color
Master Carton Size (mm)450 x 461 x 182
Gross Weight (kg)16
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
DescriptionUser-added image
Optional Input Wiring Kits are available:
PN/Ordering NoLengthEnd AEnd B
C810070M6VAR2(R)60IEC 60320 C8JST VAR-2
C1410070M6VAR2(R)60IEC 60320 C13JST VAR-2
VAR2210070M7VAR2(R)73JST VAR-2JST VAR-2
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageAttention Mark / Refer to operating manual for operating and service instructions

No Logo Applicable

CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC GB17625.1-2012, GB4943.1-2011, GB/T9254-2008

User-added image  
CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
User-added imageMedical Elec. Equip.- Part 1-11: Gen. Req. For Basic Safety & Essential Perf.- Collateral Standard - Req. For Medical Elec. Equip. & Medical Elec. Systems Used In The Home Healthcare Environment [IEC 60601- 1-11:2015 Ed.2]
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
UKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
97229624.09.375
168648412.018.75
168648554.04.16
168648812.018.75
168648954.04.16
211364236.06.25

Cos’è un alimentatore per applicazioni medicali conforme IEC 60601-1?

 

Si tratta di un convertitore che permette di alimentare, tipicamente in DC, un sistema o un componente in ambito elettromedicale, prelevando tensione AC dalla rete. Tipicamente, il case è in materiale plastico e la spina può essere a 2 o 3 poli. Esistono anche versioni open frame da alloggiare all’interno di apparecchiature medicali. La progettazione è eseguita secondo gli standard internazionali e alcuni requisiti sono specifici e particolari in confronto alle più comuni applicazioni per informatica e telecomunicazioni. Che differenze ci sono per quanto attiene la certificazione allo standard IEC 60601-1 Quarta Edizione rispetto alla vecchia IEC 60601-1 Terza Edizione?

Di fatto, le certificazioni in materia di sicurezza fissate dalla Terza Edizione continuano a valere mentre per quanto attiene gli aspetti EMI/EMC si fa riferimento alla Quarta.

Qual è la differenza fra un alimentatore per usi medicali certificato IEC 60950-1 rispetto ad uno certificato IEC 60601-1 ?

 

Sia la IEC 60950-1 che la IEC 60601-1-2 si riferiscono ad alimentatori AC/DC per uso interno o esterno ma con diversi requisiti relativi alle specifiche del sistema da alimentare. Le funzionalità di base sono ovviamente le stesse, ci si riferisce per esempio a tensione di uscita e caratteristiche meccaniche ma, per il resto, ci sono diverse differenze. I dispositivi IEC 60601, in confronto all’altra tipologia, devono essere in grado di sopportare tensioni elevate e avere basse correnti di dispersione. Inoltre, con riferimento al carico, occorre distinguere fra sistemi MOOP e MOPP. Le apparecchiature medicali devono includere uno o più sistemi di protezione ovvero Means of Protection (MOPs) per isolare i pazienti e gli operatori dal rischio di elettrocuzione. Si tratta di isolamento di sicurezza, terra di protezione, distanze di isolamento in aria o altri sistemi contro il contatto diretto. Tutti questi sistemi sono spesso utilizzati in combinazione fra loro. La norma IEC 60601-1 Terza Edizione fissa delle differenze relativamente ai rischi per i pazienti e per gli operatori. Pertanto, un sistema MOP può quindi essere classificato come MOPP (Means of Patient Protection) oppure come MOOP (Means of Operator Protection). La principale differenza sta nelle distanze limite di isolamento. Per esempio, per ottenere la rispondenza ai requisiti 2 x MOPP il livello di isolamento da garantire durante i test che prevedono l’applicazione di 4000 Vac con una distanza di di 8 mm è il doppio rispetto al caso MOPP.

Cos’è un alimentatore per usi medicali IEC 60601-1-2 e qual è la differenza fra la tipologia BF e CF?

Tali sigle si riferiscono alle tipologie B ovvero “body”, BF ovvero “body floating type” e CF ovvero “cardiac floating type. Ci si riferisce in pratica alle modalità di applicazione del dispositivo medicale al corpo del paziente con requisiti tecnici che riguardano tensione di isolamento, correnti disperse, ecc. La parola floating si riferisce all’assenza di collegamento di terra. Si tratta in questo caso di dispositivi in Classe II con isolamento doppio o rinforzato. La tipologia B si riferisce a dispositivi che operano nelle vicinanze del paziente così come definito dalla norma IEC 60601-1 ovvero senza contatto elettrico diretto e con collegamento a terra. Si tratta, per esempio, di sistemi di illuminazione, sistemi di automazione per letti, distributori automatici di medicine, macchinari a raggi x, ecc. Nel caso dei sistemi BF, invece, vi è una stretta prossimità fra paziente e apparecchiatura, si tratta per esempio di endoscopi, sistemi di monitoraggio dei parametri vitali, ecc. Nel caso CF, il collegamento è invece diretto come avviene per defibrillatori, pacemaker, elettrodi ECG intracardiaci, ecc. Per ovvie ragioni, in questo ultimo caso, è richiesto un elevatissimo livello di protezione contro l’elettrocuzione.

Cos’è un alimentatore AC-DC di tipo open frame ?

Anche noti come convertitori AC-DC, si tratta di una tipologia di alimentatori per uso da interno. Gli alimentatori AC-DC open frame sono spesso integrati in altri sistemi o alloggiati in particolari case metallici ed utilizzati per convertire la tensione da AC a DC.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è il livello VI di efficienza?

L’ordinamento numerico da I a VI si riferisce alla marcatura internazionale di prodotti in relazione al livello di efficienza di un certo prodotto. I requisiti previsti per la classificazione si basano sulla misura dell’efficienza durante il funzionamento e sulla valutazione del consumo a vuoto e a diversi livelli di carico. Il consumo a vuoto viene registrato in assenza di carico o con carico disconnesso. Il livello di efficienza VI è ormai obbligatorio in diverse nazioni per specifici prodotti o per specifiche applicazioni. La Direttiva Europea Eco-design 2009/125/EC ha di fatto inserito, per i Paesi Europei, i requisiti del livello di efficienza VI nell’ambito delle normative che regolano la vendita e l’importazione di alimentatori per uso esterno.

Come funziona un adattatore AC-DC?

L’adattatore AC-DC è un convertitore da esterno integrato all’interno di un piccolo case costruito attorno ad una spina AC per collegamento alla rete, da cui derivano anche i vari termini plug, wall plug in, plug-in o plugtop. Una volta collegato alla rete elettrica AC, la tensione viene convertita in DC per l’alimentazione del carico attraverso il cavo di uscita.

Richiesta informazioni
Call
Email
💬
Text
💁
Chat
?
Richiedi un preventivo
Ti possiamo aiutare?
Ti possiamo aiutare?