Medical/ICT/ITE/Household use Power Supply

GTM961800PWWWVV.V-T2A Image
Model Image160 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C18) Inlet, Desktop Adapter, Ac-Dc Power Supply 160 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C18) Inlet, Desktop Adapter, Ac-Dc Power Supply
Information
Model NumberGTM961800PWWWVV.V-T2A
Description160 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C18) Inlet, Desktop Adapter, Ac-Dc Power Supply 160 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C18) Inlet, Desktop Adapter, Ac-Dc Power Supply
Agency Documentshttp://www.globtek.info/certs/GTM961800P/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QC1QBEA1
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QC1QBEA1
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000QC1QBEA1
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QC1QBEA1
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QC1QBEA1
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000QC1QBEA1
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000QC1QBEA1
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000QC1QBEA1
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Esterno tipo computer
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / Alimentatore AC-DC di tipo switching
CategoryMedical/ICT/ITE/Household use Power Supply / Medical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)2.2A
Max Output Power Rating (W)180
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)176.5*74*40
Enclosure
User-added image
 
3D File Downloadhttps://www.globtek.com/dl/GTM961600-GTM961800-T2A.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM961800P16012-T2A*1213.33159.96
GTM961800P17015-T2A*1511.33169.95
GTM961800P17018-T2A*189.44169.92
GTM961800P18019-T2A*199.47179.93
GTM961800P18024-T2A*247.5180
GTM961800P18030-T2A*306180
GTM961800P18036-T2A*365180
GTM961800P18048-T2A*483.75180
GTM961800P18054-T2A*543.333179.98
GTM961800PWWWVV.V-T2A-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 (min.) @ 230VAC, 0.97 (min.) @ 115VAC
No Load Input Power:<150mW @ 230VAC (EU CoC Tier 2 compliant)
Inrush Current:30A/60A max. (cold start @ 115V/230VAC)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ. @ 115VAC and full load
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Turn-On Overshoot:5% max.
Transient Response:5% max. deviation, 1ms recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Switching Frequency:25 - 125KHz, depending on model and load condition
Power Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, dual input line fusing
Over-Current Protection:105 - 140% of rated output current, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max. for output voltage ≥ 45V), latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Standard models (No suffix):
     Class I: 20µA max.
     Class II: 70µA max.
     Class II with Functional Earth (F2): 20µA max.

Low-leakage models (-CF suffix):
     Class II with Functional Earth (F2): 10µA max.
Note 2:Standard models are designed for use in Type-B/BF medical applications. Low-leakage models are designed for use in Type-CF medical applications. (See IEC60601-1, Clause 16.6.1)
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-2700MHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Material/Construction:High impact plastic, 94V0 polycarbonate, non-vented
Size:176.5 * 74.0 * 40.0mm (±1.0mm)
AC Input Mechanical Options:Desktop: C6, C7, C14, or C18 inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Custom cordsets, cord types, and connector types
  2. Custom markings
  3. Custom housing and cordset colors
  4. Constant current/constant voltage (CC/CV) output behavior, with compliance voltage between (75% * Vout) and (100% * Vout)
  5. Short term output surge power capability, for motor applications and short term intermittent high power applications. (Up to 300W for 1 second.)
  6. IEC61000-3-2 Class C line harmonics for LED lighting applications
  7. "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  8. Reduced touch/leakage current for IEC60601-1 Type-CF applications. (Available in models with -CF suffix.)
  9. High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
  10. Tightened output voltage tolerance
  11. Reduced output ripple level
  12. Reduced output power rating
  13. Improved ingress protection (IP) rating

Output Connectors

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)465 x 415 x 225
Gross Weight (kg)16
Label Width (mm)41.0
Label Height (mm)71.0
Input Configuration
DescriptionIEC 60320/C18 AC Inlet connector, Class II, Non-Earth Ground

Mates with IEC 60320/C17 Plug
User-added image

 

      
Standard International IEC 320/C17 Cordsets    
      
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
      
Part Number/ LinkCountryPlugTerminationLength (mm)Length (Ft)
209A4062M071(R)Argentina (Type I)IRAM 2063IEC320/C1720006.6
5014112M071A(R)Australia (Type I)AS3112IEC 320/C1720006
204B4062M071(R)Brazil (Type N)NRR 14136IEC320/C1720006.6
4533502M071(R)China (Type A)GB 2099.1IEC320/C1720006.6
2074232M071C(R)Europe (2.5A, Type C)CEE 7/7IEC 320/C1720006.6
489C4232M071A(R)Europe (10A)CEE 7/17IEC320/C1720006.6
208A41111M8071A(R)India (Type D)IS 1293IEC 320/C1718006
451J3322M071AJapan (Type A)JIS 8303IEC320/C1720006.6
401P1086F071A(R)North America (Type A)NEMA 1-15PIEC 320/C1718286
401P1219F71ANorth America (Type A)NEMA 1-15PIEC 320/C1727439
4033321M8071(R)Taiwan (Type A)CNS10917IEC 320/C1718006
6104232M071A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363 (Fuse 3A)IEC 320/C1720006.6
6303742M571A(R)Thailand (Type C)TIS 166-2549IEC 320/C1725008
     
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

IEC 60601-1-11:2015
No Logo ApplicableIEC 60601-1: 2005 + C1 + C2 + A1

No Logo Applicable

CB for 60335-1:2010/COR1:2010/COR2:2010 /AMD1:2013/COR1:2014/AMD2:2016/COR1:2016

No Logo Applicable

IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008

User-added image  
CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
 
cETLus-Cert-4007497 ANSI/AAMI ES60601-1:2005 with AMD C1: 2009, AMD C2: 2010 and CAN/CSA-C22.2 No. 60601-1 2008 with COR 2:2011+ANSI/AAMI HA60601-1-11 Ed:1
User-added image
 
cETLus-Cert-60950-1 4007497 Listed
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-007.2 to IEC 62368-1:2014
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageRCM certificate SAA-200887-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request

Cos’è un alimentatore per applicazioni medicali conforme IEC 60601-1?

 

Si tratta di un convertitore che permette di alimentare, tipicamente in DC, un sistema o un componente in ambito elettromedicale, prelevando tensione AC dalla rete. Tipicamente, il case è in materiale plastico e la spina può essere a 2 o 3 poli. Esistono anche versioni open frame da alloggiare all’interno di apparecchiature medicali. La progettazione è eseguita secondo gli standard internazionali e alcuni requisiti sono specifici e particolari in confronto alle più comuni applicazioni per informatica e telecomunicazioni. Che differenze ci sono per quanto attiene la certificazione allo standard IEC 60601-1 Quarta Edizione rispetto alla vecchia IEC 60601-1 Terza Edizione?

Di fatto, le certificazioni in materia di sicurezza fissate dalla Terza Edizione continuano a valere mentre per quanto attiene gli aspetti EMI/EMC si fa riferimento alla Quarta.

Qual è la differenza fra un alimentatore per usi medicali certificato IEC 60950-1 rispetto ad uno certificato IEC 60601-1 ?

 

Sia la IEC 60950-1 che la IEC 60601-1-2 si riferiscono ad alimentatori AC/DC per uso interno o esterno ma con diversi requisiti relativi alle specifiche del sistema da alimentare. Le funzionalità di base sono ovviamente le stesse, ci si riferisce per esempio a tensione di uscita e caratteristiche meccaniche ma, per il resto, ci sono diverse differenze. I dispositivi IEC 60601, in confronto all’altra tipologia, devono essere in grado di sopportare tensioni elevate e avere basse correnti di dispersione. Inoltre, con riferimento al carico, occorre distinguere fra sistemi MOOP e MOPP. Le apparecchiature medicali devono includere uno o più sistemi di protezione ovvero Means of Protection (MOPs) per isolare i pazienti e gli operatori dal rischio di elettrocuzione. Si tratta di isolamento di sicurezza, terra di protezione, distanze di isolamento in aria o altri sistemi contro il contatto diretto. Tutti questi sistemi sono spesso utilizzati in combinazione fra loro. La norma IEC 60601-1 Terza Edizione fissa delle differenze relativamente ai rischi per i pazienti e per gli operatori. Pertanto, un sistema MOP può quindi essere classificato come MOPP (Means of Patient Protection) oppure come MOOP (Means of Operator Protection). La principale differenza sta nelle distanze limite di isolamento. Per esempio, per ottenere la rispondenza ai requisiti 2 x MOPP il livello di isolamento da garantire durante i test che prevedono l’applicazione di 4000 Vac con una distanza di di 8 mm è il doppio rispetto al caso MOPP.

Cos’è un alimentatore per usi medicali IEC 60601-1-2 e qual è la differenza fra la tipologia BF e CF?

Tali sigle si riferiscono alle tipologie B ovvero “body”, BF ovvero “body floating type” e CF ovvero “cardiac floating type. Ci si riferisce in pratica alle modalità di applicazione del dispositivo medicale al corpo del paziente con requisiti tecnici che riguardano tensione di isolamento, correnti disperse, ecc. La parola floating si riferisce all’assenza di collegamento di terra. Si tratta in questo caso di dispositivi in Classe II con isolamento doppio o rinforzato. La tipologia B si riferisce a dispositivi che operano nelle vicinanze del paziente così come definito dalla norma IEC 60601-1 ovvero senza contatto elettrico diretto e con collegamento a terra. Si tratta, per esempio, di sistemi di illuminazione, sistemi di automazione per letti, distributori automatici di medicine, macchinari a raggi x, ecc. Nel caso dei sistemi BF, invece, vi è una stretta prossimità fra paziente e apparecchiatura, si tratta per esempio di endoscopi, sistemi di monitoraggio dei parametri vitali, ecc. Nel caso CF, il collegamento è invece diretto come avviene per defibrillatori, pacemaker, elettrodi ECG intracardiaci, ecc. Per ovvie ragioni, in questo ultimo caso, è richiesto un elevatissimo livello di protezione contro l’elettrocuzione.

Cos’è un adattatore esterno AC-DC ?

Anche noti come adattatori AC o convertitori AC-DC, si tratta di una tipologia di alimentatori esterni. Alcune apparecchiature elettriche necessitano di alimentazione di potenza ma non dispongono di una circuiteria interna per poter gestire un collegamento diretto alla rete. In casi del genere, un alimentatore esterno viene utilizzato per convertire la tensione AC di rete in tensione DC adatta per l’alimentazione dell’apparecchiatura in questione.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è un alimentatore conforme alla norma IEC 62368-1:2018 ?

Tale norma fissa i requisiti di sicurezza per sistemi elettrici ed elettronici in ambito audio, video, telecomunicazioni e applicazioni per uffici e similari per tensioni non superiori a 600 V. I requisiti fissati riguardano i dispositivi di protezione e la loro effettiva implementazione nel sistema allo scopo di prevenire danni a persone o cose per elettrocuzione o incendio. Un alimentatore conforme alla IEC 62368-1 è pertanto un convertitore AC/DC che ha superato i test previsti da tale norma.

Gli alimentatori IEC 62368-1 possono essere considerati come succedanei di quelli conformi IEC 60950-1?

È già in corso la transizione delle norme IEC 60065 e 60950-1 verso la nuova IEC 62368-1. In Nord America le certificazioni ETL e UL 60950-1 continueranno a rimanere valide, a meno di ulteriori novità.

Vi sono differenze sostanziali fra la IEC 60950-1 e la IEC 62368-1 per gli alimentatori?

Sebbene l’impostazione generale della nuova norma appaia diversa, di fatto la maggior parte dei prodotti che risultavano conformi alla IEC 60950-1 lo sono anche per la IEC 62368-1 apportando minime modifiche o, in taluni casi, senza alcuna modifica necessaria. In ogni caso, GlobTek continuerà a produrre alimentatori IEC 60950-1 a meno di ulteriori novità.

Cos’è il livello VI di efficienza?

L’ordinamento numerico da I a VI si riferisce alla marcatura internazionale di prodotti in relazione al livello di efficienza di un certo prodotto. I requisiti previsti per la classificazione si basano sulla misura dell’efficienza durante il funzionamento e sulla valutazione del consumo a vuoto e a diversi livelli di carico. Il consumo a vuoto viene registrato in assenza di carico o con carico disconnesso. Il livello di efficienza VI è ormai obbligatorio in diverse nazioni per specifici prodotti o per specifiche applicazioni. La Direttiva Europea Eco-design 2009/125/EC ha di fatto inserito, per i Paesi Europei, i requisiti del livello di efficienza VI nell’ambito delle normative che regolano la vendita e l’importazione di alimentatori per uso esterno.

Come funziona un adattatore AC-DC?

L’adattatore AC-DC è un convertitore da esterno integrato all’interno di un piccolo case costruito attorno ad una spina AC per collegamento alla rete, da cui derivano anche i vari termini plug, wall plug in, plug-in o plugtop. Una volta collegato alla rete elettrica AC, la tensione viene convertita in DC per l’alimentazione del carico attraverso il cavo di uscita.

Richiesta informazioni
Call
Email
💬
Text
💁
Chat
?
Richiedi un preventivo
Ti possiamo aiutare?
Ti possiamo aiutare?