Request Information Download PDF
GTM91120-30VV-F GTM91120-30VV-F
Information
Model NumberGTM91120-30VV-F
DescriptionGTM91120-30VV-F, Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 or EQUIVALENT, Output Rating: 30 Watts, 5-48V in 0.1V increments, Approvals: CB EN/IEC 60335-1 CB CB CE CE China RoHS cUL FCC GOST-R Level V RoHS 2 SIQ SIQ Ukraine VCCI WEEE cRUus CE ETL CB
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0Oa000000FysLkEAJ
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
RoHS/RoHS3 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0Oa000000FysLkEAJ
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)101.6x50.8x22.30
Enclosure           User-added image

IMPORTANT INSTALLATION NOTES:
FOR PROPER  INSULATION AND GROUNDING RELIABILITY, FOLLOW EITHER OPTIONS BELOW

 
OPTION 1: USE NYLON 4-40 SCREWS AND  NYLON STAND-OFF FOR ALL MOUNTING  HOLES  AND ADD JUMPER 
                    WIRE OPTION SHOWN BELOW FOR  EARTH CONNECTION BETWEEN MOUNTING HOLES 2  AND 4.
  User-added image          RING TERMINAL, AMP P/N: 8-34142-5 AWG 18 STRANDED WIRE,
                                                            GREEN, 130+20,-0 mm LENGTH
 
OPTION 2. USE METALLIC 4-40 SCREWS AND METALLIC STAND-OFF  FOR HOLES 2 AND 4 AND USE NYLON 4-40  
                   SCREWS AND NYLON STAND-OFF FOR HOLES 1 AND 3.   
                   OPTION 2 IS ONLY  APPLICABLE IF SYSTEM CHASSIS, WHERE THE POWER SUPPLY IS MOUNTED IS MADE
                   OUT OF METAL.
 
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM91120-3007.5-2.5-F* 5420 RFQ
GTM91120-3007.5-1.5-F* 63.7522.5 RFQ
GTM91120-3010.5-1.5-F* 92.7724.93 RFQ
GTM91120-3014.5-2.5-F* 122.530 RFQ
GTM91120-3019.5-4.5-F* 15230 RFQ
GTM91120-3019.5-1.5-F* 181.6629.88 RFQ
GTM91120-3024-F* 241.2530 RFQ
GTM91120-3036-F* 360.8329.88 RFQ
GTM91120-3048-F* 480.62530 RFQ
* (Final ordering #/Part No to be defined)
SpecificationsA) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: 100-240 Vac
2. Input Current: 1.5 A RMS max
3. Input Frequency: 47 - 63 Hz
4. Output power (rated): 30Watts max
Note: Refer to Power Supply information on page 2 for the corresponding rated output power for the specific output voltage.
5. Output Regulation: +/- 5% measured at the output connector
6. Line Voltage Regulation: +/- 2% typical measured at full load
7. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
Optional low ripple option available (RFP4579)
8. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
9. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
10. Hold-Up Time: 8mS typical @ nominal input voltage and full load
11. Inrush Current: 60A maximum cold start @ 240Vac input
12. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: <100 uA at 240Vac input voltage
3. MTBF: 200,000 hours @ 25°C ambient temperature
4. Operating Temperature: 0°C to 40°C ambient temperature

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Humidity: 0% to 90% relative humidity
3. Storage Temperature: -10°C to 80°C
4. Cooling: Convection
Derating Curve
Qty (ea.)/Carton50
Individual Box/Gift Box Size (mm)117*82*58
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.7
Label Width (mm)15.0
Label Height (mm)21.0
Input Configuration
Description5-PIN PC BOARD 3.96 mm WAFER CONNECTOR, JVE P/N: 24W1180-05S10-01T-3.6-R2A-CG01 or EQUIVALENT
User-added image




Approvals
LogoDescription
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added image  CE Mark: tested to comply with EN 60601-1-2:2007 Medical electrical equipment Part 1-2: - Mark is on the label or Molded in the case
User-added imageIEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: Gen. Req. for Basic Safety &Essential Perf.- Collateral Standard - Req. for Medical Elec. Equip. & Medical Elec.Systems Used in the Home Healthcare Environment
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added imagecRUus UL Recognized Component E341351 UL 60950-1, 2nd Edition, 2011-12-19 (Information TechnologyEquipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12
No LogoDesigned to meet EN 60601-1:2006 + A11:2011 +A1:2013 3rd Edition
User-added image
FCC PART 15 CLASS B
User-added image
 
GOST-R mark for Russia(Document: http://www.globtek.com/html/iso_certificates/GT_GOST-R.pdf). 03/15/2015. Due to lack of demand, GlobTek will not be renewing it's GOST certification. Please contact your sales engineer for pricing on EAC.
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageRCM certificate SAA150575; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
Serial Number Information
User-added image
IEC/EN60335-1
SIQ IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 volts
User-added image
IEC/EN60601-1
SIQ Mark License EN60601-1, 3rd edition
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products
SKUVolts OutCurrent Out (Amps)Connector
181888122.5P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
266913241.25P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
20543554P/N: 24W1170-04S10-01T-3.4-R2A-CS01; 4-PIN PC BOARD 2.5 mm WAFER WITH BOX CONNECTOR
News Releases
TitleWeb Link
CB Certificate IEC 60335-1:2010 (5th ed.) CB report IEC 60335-1:2010 (5th Ed.) and EN 60335- 1:2012.

Richiesta informazioni